For availability of the split refrigeration units, please contact the local sales company in your country.
|
WSC2 1800 PF |
WSC2 2200 PF |
WSC2 2800 PF |
WSC2 4100 PF |
WSC2 5500 PF |
Cooling capacity [W]¹ |
1800/1600 |
2200/1900 |
2800/2300 |
4100/3400 |
5500/4600 |
Room volume up to [m³]² |
30 |
40 |
55 |
90 |
130 |
Cold room temperature adjustment range [°C] |
+5 to +20 |
+5 to +20 |
+5 to +20 |
+5 to +20 |
+5 to +20 |
Allowed ambient temperature [°C] ³ |
-15 to +43 |
-15 to +43 |
-15 to +43 |
-15 to +43 |
-15 to +43 |
Refrigerant / GWP |
R513A/573 |
R513A/573 |
R513A/573 |
R513A/573 |
R513A/573 |
Sound pressure level day/night [dB(A)] ⁴ |
34/34 |
34/34 |
39/36 |
40/37 |
40/37 |
Voltage / Phases / Frequency (V/-/Hz) |
230/1/ 50 |
230/1/ 50 |
400/3/50 |
400/3/50 |
400/3/50 |
Defrosting type |
Circulating air |
Circulating air |
Circulating air |
Circulating air |
Circulating air |
Dimensions condensing unit HxWxD [mm] |
600x900x350 |
600x900x350 |
840x1030x425 |
840x1030x425 |
840x1030x425 |
Dimensions evaporator HxWxD [mm] |
455x752x430 |
455x752x430 |
455x752x430 |
455x1212x430 |
455x1212x430 |
¹ Condensing unit; evaporation temperature t₀ -5°C, ambient temperature + 32°C / 43°C; evaporator superheat 10K; influences of installation location and other refrigeration circuit components must be considered independently
² Basis of calculation for room size: room temperature +5°C, ambient temperature +25°C, heat extraction from goods 15 K, operating time 16 h/day, goods handling 1/7 per day, inspection and lighting 0.5 h / day
³ Max. compressor inlet superheat 20K
⁴ Based on AR5 / IPCC
⁵ Condensing unit, A-weighted equivalent sound pressure level at a distance of 10m
|
WSC2 1700 PM |
WSC2 2100 PM |
WSC2 2600 PM |
WSC2 3700 PM |
WSC2 5100 PM |
WSC2 6400 PM |
Cooling capacity [W]¹ |
1700/1400 |
2100/1800 |
2600/2100 |
3700/3100 |
5100/4300 |
6400/5400 |
Room volume up to [m³]² |
25 |
35 |
45 |
70 |
105 |
140 |
Cold room tempe- rature adjustment range [°C] |
+2 to +20 |
+2 to +20 |
+2 to +20 |
+2 to +20 |
+2 to +20 |
+2 to +20 |
Allowed ambient temperature [° C] ³ |
-15 to +43 |
-15 to +43 |
-15 to +43 |
-15 to +43 |
-15 to +43 |
-15 to +43 |
Refrigerant / GWP ⁴ |
R513A/573 |
R513A/573 |
R513A/573 |
R513A/573 |
R513A/573 |
R513A/573 |
Sound pressure level day / night [dB(A)] ⁵ |
34/34 |
34/34 |
39/36 |
40/37 |
40/37 |
41/38 |
Voltage / Phases / Frequency (V/-/Hz) |
230/1/50 |
230/1/50 |
400/3/50 |
400/3/50 |
400/3/50 |
400/3/50 |
Defrosting type |
Electrical |
Electrical |
Electrical |
Electrical |
Electrical |
Electrical |
Dimensions condensing unit HxWxD [mm] |
600x900x350 |
600x900x350 |
840x1030x425 |
840x1030x425 |
840x1030x425 |
1245x1030x425 |
Dimensions evaporator HxWxD [mm] |
455x752x430 |
455x752x430 |
455x752x430 |
455x1212x430 |
455x1212x430 |
455x1672x430 |
¹ Condensing unit, Evaporation temperature t₀ -7°C; ambient temperature + 32°C / 43°C; evaporator superheat 10K; influences of installation location and other refrigeration circuit components must be considered independently
² Basis of calculation for room size: Room temperature +2°C, Ambient temperature +25°C, heat extraction from goods 15K, operating time 16 h/day, goods handling 1/7 per day, inspection and lighting 0.5 h / day
³ Max. Compressor inlet superheat 20K
⁴ Based on AR5 / IPCC
⁵ Condensing unit, A-weighted equivalent sound pressure level at a distance of 10m
|
WSC2 2100 FV |
WSC2 2700 FV |
WSC2 3400 FV |
WSC2 5000 FV |
WSC2 6700 FV |
Cooling capacity [W]¹ |
2100/1800 |
2700/2300 |
3400/2800 |
5000/4200 |
6700/5700 |
Room volume up to [m³]² |
35 |
50 |
65 |
105 |
150 |
Cold room temperature adjustment range [°C] |
+5 to +20 |
+5 to +20 |
+5 to +20 |
+5 to +20 |
+5 to +20 |
Allowed ambient tem-perature [°C] ³ |
-15 to +43 |
-15 to +43 |
-15 to +43 |
-15 to +43 |
-15 to +43 |
Refrigerant / GWP ⁴ |
R513A/573 |
R513A/573 |
R513A/573 |
R513A/573 |
R513A/573 |
Sound pressure level day / night [dB(A)] ⁵ |
34/34 |
34/34 |
39/36 |
40/37 |
40/37 |
Voltage / Phases / Frequency (V/-/Hz) |
230/1/50 |
230/1/50 |
400/3/50 |
400/3/50 |
400/3/50 |
Defrosting type |
Circulating air |
Circulating air |
Circulating air |
Circulating air |
Circulating air |
Dimensions condensing unit HxWxD [mm] |
600x900x350 |
600x900x350 |
840x1030x425 |
840x1030x425 |
840x1030x425 |
Dimensions evaporator HxWxD [mm] |
455x752x430 |
455x752x430 |
455x1212x430 |
455x1212x430 |
455x1672x430 |
¹ Condensing unit, Evaporation temperature t₀ 0°C; ambient temperature + 32°C / 43°C; evaporator superheat 10K; influences of installation location and other refrigeration circuit components must be considered independently
² Basis of calculation for room size: Room temperature +8°C, Ambient temperature +25°C, heat extraction from goods 15K, operating time 16 h/day, goods handling 1/7 per day, inspection and lighting 0.5 h / day
³ Max. Compressor inlet superheat 20K
⁴ Based on AR5 / IPCC
⁵ Condensing unit, A-weighted equivalent sound pressure level at a distance of 10m
Viessmann is one of the leading European manufacturers of commercial refrigeration and clean room solutions, renowned for their energy efficiency and sustainability together with ease of use and maintenance. Viessmann's refrigeration product and service portfolio includes remote and plug-in refrigeration cabinets, refrigeration systems and cold and clean room solutions as well as accessories and related services. The refrigeration products are manufactured at Viessmann factories in Germany and Finland and are represented by local sales offices in 18 countries throughout Europe, backed up by an extensive network of partner companies.